Eight Outputs
The G-02X can
supply a clock signal to a maximum of eight devices. Output can be
switched ON and OFF for each terminal. The unit has four 10 MHz sine
wave clock output terminals. The other four output terminals (A x 2 and B
x 2) enable clock signals to be output at 100 kHz, 10 MHz (square
wave), and the basic frequency of 44.1 kHz/48 kHz, up to a maximum
frequency of 22.5792 MHz/24.576 MHz, and separate output frequencies can
be set for each terminal.
The Specs
Clock outputs |
CLOCK OUT |
44.1 kHz setting |
44.1, 88.2, 176.4, 352.8, 705.6 kHz |
1.4112, 2.8224, 5.6448, 11.2896, 22.5792 MHz |
48 kHz setting |
48, 96, 192, 384, 768 kHz |
1.536, 3.072, 6.144, 12.288, 24.576 MHz |
Both settings |
100 kHz, 10 MHz |
Connectors |
BNC x 4 |
Output level |
Rectangular wave: TTL level / 75 Ω |
10MHz OUT |
10 MHz |
Connectors |
BNC x 4 |
Output level |
Sine wave: 0.5 ± 0.1 Vrms / 50 Ω |
Standard frequency input (EXT IN) |
Input frequency |
10MHz (within ±10ppm) |
Connector |
BNC x 1 |
Input levels |
Sine wave: 0.5-1.0 Vrms/50 Ω Square wave: TTL level/10 kΩ |
OCXO (Chrystal oscillator) |
Until oscillator stabilizes after power turned on |
10 minutes |
Frequency stability |
Within ±0.015 ppm (0°C to 70°C) |
Frequency precision |
Within ±0.01 ppm Typ (when shipped new)(ppm = 10 -6) |
General |
Power supply |
AC 230V, 50Hz AC 120V, 60Hz AC 220V, 60Hz |
Dimensions (W x H x D)
(including protrusions) |
445 x 107 x 359 mm
(17 5/8″ x 4 1/4″ x 14 1/4″) |
Weight |
11.3kg (25 lb) |
Included accessories |
Power cord x 1, Felt pads x 3, Owner's manual x 1, Warranty card x 1 |